CLAUSE CODE: QC114    This clause was archived as of 01/07/2016
  CLAUSE TITLE: Heat Treat Requirements


QC114 HEAT TREAT REQUIREMENTS

 

General Requirements

·          The Contractor shall provide objective evidence (photographs, illustrated diagram) of the following:

o    Thermocouple placement

o    Part loading placement

·          The Contractor shall provide recorded data from the temperature measurement device.

 

Reporting Requirements

·          The Contractor performing the heat treat shall provide a signed certification that states the following:

o    Heat treat control number

o    Reference specification

o    JPL purchase order number

o    Part number

o    Alloy

o    Temper/Strength designation

o    Quantity of parts

o    Identification of furnace(s) used

o    Furnace class in which the furnace was certified per AMS 2750

o    Actual thermal processing times and temperatures used

o    Atmosphere type

o    Type of cooling performed

 

Flow Down Requirements

·          This clause mandates that all requirements shall be flowed down to Sub-tier Suppliers.