QC114 HEAT TREAT REQUIREMENTS
General Requirements
·
The Contractor shall provide objective
evidence (photographs, illustrated diagram) of the following:
o Thermocouple
placement
o Part
loading placement
·
The Contractor shall provide recorded data
from the temperature measurement device.
Reporting
Requirements
·
The Contractor performing the heat treat
shall provide a signed certification that states the following:
o
Heat treat control number
o
Reference specification
o
JPL purchase order number
o
Part number
o
Alloy
o
Temper/Strength designation
o
Quantity of parts
o
Identification of furnace(s) used
o
Furnace class in which the furnace was
certified per AMS 2750
o
Actual thermal processing times and
temperatures used
o
Atmosphere type
o
Type of cooling performed
Flow Down Requirements
·
This
clause mandates that all requirements shall be flowed down to Sub-tier
Suppliers.