QC114a - Heat Treat Requirements:
General
The Subcontractor shall provide objective evidence (photographs, illustrated diagram) of the following:
- Thermocouple placement
- Part loading placement
The Subcontractor shall provide recorded data from the temperature measurement device.
Reporting Requirements
The Subcontractor performing the heat treat shall provide a signed certification that states the following:
- Heat treat control number
- Reference specification
- JPL subcontract/purchase order number
- Part number
- Alloy
- Temper/strength designation
- Quantity of parts
- Identification of furnace(s) used
- Furnace class in which the furnace was certified per AMS 2750
- Actual thermal processing times and temperatures used
- Atmosphere type
- Type of cooling performed