CLAUSE CODE: QC47c    This clause was archived as of 02/17/2010
  CLAUSE TITLE: Pre-Cap Inspection On Electronic Parts (JPL MIP)


QC47c PRE-CAP INSPECTION ON ELECTRONIC PARTS (JPL MIP):

 

JPL Mandatory Inspection Points (MIPs) shall be required where visual inspection access to hardware may be obscured by the next assembly task. These inspection points shall be inserted into Contractor’s shop planning or routing documents upon review by JPL project and quality representatives. This planning shall have no subsequent alteration by Contractor without first obtaining approval from the JPL PQA liaison, and subsequent approval of planning changes post-revision.

Pre-cap visual inspection shall be performed by the JPL Quality Assurance representative on all packaged flight Application Specific Integrated Circuits (ASICs), hybrid microcircuits, Multi-Chip Modules (MCMs), crystal oscillators, and non-standard relays.

Hybrid flight lots shall be subjected to 100% source inspection. The source inspection team shall include JPL representatives.

Contractor shall promptly notify the JPL Procurement Quality Assurance (PQA) office at http://eis.jpl.nasa.gov/qa/PQA/servicerequest.cfm so the appropriate inspection can be coordinated. The following phone number may be accessed if necessary: (818) 393-7593.

Locale

Business days advance notice

Notes

Local: In-state

3 days

Minimum required

National: Domestic

5 days

Minimum required

International

10 days

Long lead time/forecasting desired